Shielded and unshielded constructions.
Copper- and aluminum-conductor configurations.
Multiple conductor sizes and insulation options.
Electric vehicles, energy storage systems and related high-voltage connections.
Unshielded high-voltage cables; shielded high-voltage cables; silicone-insulated cables with copper or aluminum conductors.
| Cable type | Size (mm²) | OD (mm) | Conductor construction | Conductor | Voltage options (V) | Rated current (A) | Rated temperature |
| Unshielded EV high-voltage cable | 50 | 12.8 | 1596/0.20BS | Oxygen-free copper | 600 / 1000 / 1500 | 200 | -40 to +125 °C |
| Unshielded EV high-voltage cable | 70 | 15.5 | 2223/0.20BS | Oxygen-free copper | 600 / 1000 / 1500 | 250 | -40 to +125 °C |
| Unshielded EV high-voltage cable | 95 | 18.5 | 3024/0.20BS | Oxygen-free copper | 600 / 1000 / 1500 | 300 | -40 to +125 °C |
| Shielded EV high-voltage cable | 50 | 12.8 | 1596/0.20BS | Oxygen-free copper | 600 / 1000 / 1500 | 200 | -40 to +125 °C |
| Shielded EV high-voltage cable | 70 | 15.5 | 2223/0.20BS | Oxygen-free copper | 600 / 1000 / 1500 | 250 | -40 to +125 °C |
| Silicone-insulated EV high-voltage cable | 35 | 14 | 1121/0.20BS | Oxygen-free copper | 600 / 1000 / 1500 | 180 | See silicone conditions below |
| Silicone-insulated EV high-voltage cable | 70 | 14.8 | 351/0.50AL | Aluminum | 600 / 1000 / 1500 | 250 | See silicone conditions below |
| Size (mm²) | Rated current (A) | Conductor construction | Conductor diameter (mm) | Unshielded OD (mm) | Shielded OD (mm) |
| 2.5 | 20 | 80/0.20mm | 2.1 | 3.35-3.65 | 5.45-5.75 |
| 4 | 30 | 128/0.20mm | 2.75 | 3.4-3.6 | 5.6-5.8 |
| 6 | 40 | 192/0.20mm | 3.3 | 4.1-4.3 | 6.2-6.4 |
| 10 | 60 | 323/0.20mm | 4.6 | 5.7-5.9 | 8.3-8.7 |
| 16 | 80 | 513/0.20mm | 5.6 | 7.65-7.95 | 11.0-11.6 |
| 25 | 120 | 798/0.20mm | 7 | 8.3-8.7 | 11.7-12.1 |
| 35 | 180 | 1121/0.20mm | 8.2 | 9.9-10.3 | 13.9-14.3 |
| 50 | 200 | 1596/0.20mm | 10.18 | 12.0-12.2 | 15.2-15.5 |
| 70 | 250 | 2223/0.2mm | 11.6 | 15.15-15.45 | 19-19.4 |
| 95 | 300 | 3024/0.20mm | 13.5 | 17.35-17.65 | 22.2-22.8 |
| 120 | 350 | 3820/0.20mm | 15.6 | 20-20.6 | 23.2-23.8 |
| Condition | Specification |
| Rated temperature | -60 to +200 °C |
| Continuous operating temperature | Up to +180 °C |
| Minimum operating ambient temperature | -60 °C |
| Minimum installation ambient temperature | 0 °C |
| Bend radius | Greater than 6 × cable OD |
| Insulation | Silicone rubber |