Blind mating for module-to-chassis fluid connections.
Standard LTF, connect-under-pressure LTFP and pressure-relief LTFX variants.
Multiple plug, socket and mounting-interface configurations.
Board modules, chassis and cabinet liquid cooling connections.
LTF-3, -5, -8, -12 and -25; LTFP-3 and -5; LTFX-3, -5 and -8.
| Category | Parameter | LTF-3 | LTF-5 | LTF-8 | LTF-12 | LTFP-3 | LTFP-5 |
| Performance | Pressure resistance (MPa) | ≥2.25 (hydraulic); ≥1.75 (pneumatic) | |||||
| Minimum burst pressure (MPa) | 6 | ||||||
| Flow coefficient Kv (m³/h) | 0.22 | 0.72 | 2 | 4.3 | 0.18 | 1.01 | |
| Maximum working flow rate (L/min) | 2.1 | 5.9 | 15 | 33.9 | 2.1 | 5.9 | |
| Maximum fluid loss per connection/disconnection cycle (mL) | 0.02 | 0.02 | 0.03 | 0.05 | 0.02 | 0.02 | |
| Maximum mating force (N) | 60 | 80 | 90 | 150 | 80 | 90 | |
| Environmental | Low temperature | -55 °C | |||||
| High temperature | +95 °C | ||||||
| Salt spray | ≥96 h | ||||||
| Cyclic damp heat | 240 h | ||||||
| Mechanical | Vibration | GJB 360B-2009, Method 214; no leakage at 1 MPa internal pressure during the specified test. | |||||
| Shock | GJB 360B-2009, Method 213; no leakage at 1 MPa internal pressure during the specified test. | ||||||
| Mating durability | 1,000 cycles | ||||||
| Materials | Housing | AL: Hard-anodized aluminum alloy; SS: Passivated stainless steel | |||||
| Seal materials (material temperature ranges) | JE: EPDM (-55 °C to +125 °C) JM: Fluorosilicone rubber (-55 °C to +155 °C) | ||||||